Choose the brand aligned with your industry so we can best serve your needs.
For researchers, scientists, and technical professionals: Your one-stop shop for the complete range of laboratory, production, and safety products and services.
Instruments and systems for gas and ion chromatography, HPLC and low-pressure liquid chromatography with various detection methods; includes configurable components, parts, and accessories; includes gravity-flow liquid chromatography supplies.
This replacement active preheater is constructed from MP35N material, featuring a 0.005 in. inner diameter and an 18.5 in. length. It is specifically designed for integration into ACQUITY Arc and ACQUITY Arc Bio CM-A systems, supporting configurations with either 6 columns or 4x 50 mm columns.
Replacement part for active preheater systems.
Constructed from MP35N material.
Features a 0.005 in. inner diameter.
Measures 18.5 in. in length.
Designed for use with ACQUITY Arc and ACQUITY Arc Bio CM-A systems.
Compatible with 6 column or 4x 50 mm column configurations.
Categorized as a mechanical type component.
Suitable for UPLC system applications.
Recommended for replacement as required.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
These columns are general purpose, high-efficiency columns based on a solid-core particle, designed to offer balanced retention of acids, bases, and neutrals across low and mid-range pH conditions.
Chemistry: C18
Separation mode: Reversed-phase
Particle substrate: Silica
pH range: 2 to 8 pH
Maximum pressure: 18000 psi (1240 bar)
Endcapped: Yes
Silanol activity: Low
Particle shape: Spherical
Particle size: 2.7 μm
Endfitting type: Parker-style
Pore size: 90 Å
Format: Method validation kit
Surface area: 100
System compatibility: HPLC
Particle technology: Solid-core
USP classification: L1
Internal diameter: 2.1 mm
Length: 75 mm
Carbon load: 6.6 %
eCord: Yes
Units per package: 3 pk
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
This rebuild kit is specifically designed for a fluidics selector valve. It is an essential component for the maintenance and repair of various mass spectrometers. The kit ensures the continued optimal performance of your analytical instruments by providing the necessary parts to rebuild the selector valve.
Type: Rebuild kit
System type: MS (Mass Spectrometer)
Replacement schedule: As required
Ensures continued optimal performance of analytical instruments
Compatible with Synapt G2, Synapt G2-S, Synapt G2-Si, Xevo QTof, Xevo G2, Xevo G2-S, Xevo G2-XS, Vion, Xevo TQ, Xevo TQ-S, and Xevo TQ-XS mass spectrometers.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
The 2 mL coiled sample loop, stainless steel, is the standard sample loop installed in the U6K Injector and used on the Rheodyne injector and Separation Modules.
Loop design
Compatible with HPLC systems
Constructed from stainless steel
2 mL volume
Replacement as required for optimal performance
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Method validation kits provide columns of three different batches. Phenyl columns offer complementary selectivity to C18 stationary phases. The particle morphology delivers high efficiency and lower backpressures compared to fully porous particles of similar size. These columns provide ultra-low column MS bleed, long lifetimes, and excellent peak shape.
Phenyl chemistry for reversed phase separation.
Silica particle substrate.
pH range of 2 to 8.
Maximum pressure of 18000 psi (1240 Bar).
Particle size of 2.7 μm.
Pore size of 90 Å.
Inner diameter of 2.1 mm.
Length of 30 mm.
Includes 3 units per package.
Compatible with UPLC and UHPLC systems.
Solid core particle technology.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
This power cord is designed for use with Waters laboratory equipment, providing reliable power connection. It features an IEC C13 connector and is rated for 10 A and 125 V, suitable for use in Taiwan.
Equipped with an IEC C13 connector.
Rated for 10 A current.
Designed for 125 V power systems.
2.5 m in length.
Compatible with power outlets in Taiwan.
Suitable for various LC, MS, and data products.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
This tube assembly is designed for connecting a degasser to an i2 V component within an ACQUITY APC p-ISM system, ensuring reliable fluid transfer for optimal system performance.
Designed for connection between degasser and i2 V.
Ensures reliable fluid transfer.
Supports optimal system performance.
Compatible with ACQUITY APC p-ISM systems.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
CORTECS Shield RP18 method validation kits offer complementary selectivity to C8 and C18 stationary phases. Featuring an embedded carbamate group, they provide alternate selectivity for phenolic compounds. The solid-core particle morphology ensures high efficiency and lower backpressures.
Complementary selectivity to C8 and C18 stationary phases
Alternate selectivity for phenolic compounds due to embedded carbamate group
Solid-core particle morphology for high efficiency and lower backpressures
Balanced retention of acids, bases, and neutrals at low and mid-range pH
Excellent peak shape for basic analytes
Chemistry: C18, Reversed phase
pH range: 2 to 8 pH
Maximum pressure: 18000 psi (1240 Bar)
Particle size: 1.6 μm
Pore size: 90 Å
Dimensions: 2.1 mm ID x 150 mm Length
Units per package: 3 pk
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More